CSK-Touch Digital room corrector with touchscreen

  • Connection is only possible on PelTec, BioTec-L, BioTec-Plus and Cm Pelet-set Touch with CM2K
  • On BioTec plus, BioTec-L and Cm Pelet-set Touch connection is possible also with CM-Wifi box
  • Changing set room temperature
  • Basic control of the boiler
  • Set of timers.
  • Weather forecast

 

CSK (analog room corrector):

  • Possibility of set room temperature correction (according room temperature set on boiler regulation).
  • Posibillity to turn off heating circuit where room corrector is installed.
  • It can be connected only to the CM2K module, BioTec-L boiler and Cm Pelet-set Touch direct.

CM-WiFi box (boiler monitoring and controling through internet):

  • Possibility of boiler monitoring with the PC, mobile phone, laptop, etc.
  • Possibility to turn on / turn off boiler, temperatures adjustment, warning and error alarms by the PC, mobile phone,
    laptop, etc.
  • Possibility of connection to the PelTec, Cm Pelet-set Touch, EKO-CKS P Unit, EKO-CKS Multi Plus boilers.

 

CAL (error and warning sound and light information)):

  • Module for sound or light information about boiler error and warning.
  • Possibility of connection to the PelTec,BioTec-L, BioTec Plus, Cm Pelet-set Touch, EKO- CKS P UNIT, EKO-CKS Multi Plus boilers.

CM2K (additional heating circuits control):

  • Possibility to control up to 2 heating circuits according to outside temperature and heating circuit curve (controling up to 2 mixing valves with motor actuators and up to 2 heating circuit pumps or up to 2 DHW circuits or up to 2
    recirculation circuits or up to 2 DHW circuits+recirculation).
  • Possibility to connect up to 2 room correctors (additional equipmnet).
  • Possibility to connect up to 4 CM2K modules (8 heating circuits).
  • Possibility of connection to the PelTec, BioTec-L, BioTec Plus, Cm Pelet-set Touch, EKO-CKS P UNIT, EKO-CKS Multi Plus.

 

CM-GSM (boiler status information through SMS messages):

  • Request for the boiler status phase of work, boiler temperature, through an SMS message in the selected language.
  • Notification of the boiler status through the mobile network text message or call (errors, warning..).
  • Boiler start/stop by SMS.
  • Possibility of internet connection through mobile data connection (CPRS, SIM card with enabled call and mobile data
    connection is neccessary)..
  • Possibility of connection to the PelTec, BioTec-L, BioTec Plus, Cm Pelet-set Touch, EKO-CKS P UNIT, EKO-CKS Multi Plus.

Dust extraction cyclone for pellet suction feeding system, type: CVDOP:

  • The cyclone is used for dust extraction from pellet suction feeding system in order to prevent dust accumulation in seasonal pellet storage through a longer usage period.
  • Right and left version

 

CMNET (boiler cascade connection):

  • Possibility to cascade control 2 to 8 boilers.
  • For cascade of 2 boilers = 1x CMNET, for cascade 3 to 8 boilers = every boiler one CMNET.
  • Connection to the boilers by UTP cables.
  • Possibility of connection to the PelTec,BioTec-L, BioTec Plus, Cm Pelet-set Touch, EKO- CKS P UNIT, EKO-CKS Multi Plus boilers.

Centrometal d.o.o. shall not be responsible for possible incorrect data caused by error made in transcription and all figures and diagrams are for explanatory purposes only and relevant adjustment have to be made at the spot. In any case, it reserves the right to modify its products as deemed to be required and useful without any prior notification.