Il sito web in italiano e in fase di produzione! Premendo la link di sotto, potete scaricare il nostro catalogo! LINK
The control unit is a mandatory additional equipment. It is possible to order an additional panel (screen) as additional equipment.
The HPCU360iCMP control unit is intended for a heat pump control and for controlling of space heating and cooling, and for domestic hot water (DHW) preparation as well.
The control unit is operated using a touch screen. Parameters are edited by touching the selected symbol on the control panel screen.
The control unit controls the operation of the a heat pump according to demand for space heating or cooling.
The control unit can control one direct heating/cooling circuit and two mixing heating/cooling circuits, and it can be additionally expanded with a module for two heating/cooling circuits HPx2kCM.
HPCU360iCM – older models (split and mono) and new Arctic models (split model 6-16 kW and mono 22/30 kW)
HPCU360iCMP – new mono P series (5-16 kW)
HPx2kCM – module for two additional heating/cooling circuits for control unit HPCU360iCM(P)
HPxTouchCM – room panel for control unit HPCU360iCM(p)
The HPx40CM room thermostat is designed for wireless cooperation with HPrfCM radio transmission module, which is wired to the control unit. The thermostat is installed in a selected room, e.g. a living room and is designed to maintain a preset room temperature by sending a radio signal to a module connected to the control unit. The implemented encrypted, two-way radio communication allows the transmission of information from the control unit to the thermostat alarm statuses of the control unit and external temperature values. The thermostat on the backlit LCD display shows information about the room temperature value, selected operating mode, current time with simultaneous clock synchronization with the control unit.
HPe2/4CM may only be used in conjunction with a heat pump, as a supplementary heat source controlled via a heat pump. Any other use will be considered improper and the manufacturer assumes no responsibility for damage caused by improper use.
To ensure proper use, it is necessary to follow the operating instructions, data on the nameplate and technical data.
The HPe2/4CM is designed to support a heat pump and can only work in conjunction with a heat pump. This device does not have a working thermostat (it has a protective thermostat), but forwards the information from the temperature sensor to the thermoregulator of the heat pump. The heat pump thermostat decides whether and when the electric heater will be switched on.
HPe2/4CM is designed for wall mounting. The HPe2/4CM is wall-mounted using the supplied mounting kit.
The HPnet300CM Internet module enables operation remote control (on-line) HPCU360iCM control unit via Internet.
Hot water boilers WP/E are intended for heating and accumulating domestic hot water by connecting to a heat pump circuit or another source in the boiler room or to another heat source within some technological process. The boilers are made of high-quality steel and are enamelled in two layers according to DIN 4753, which guarantees high hygienic conditions. By using modern technologies and proven technical solutions, a high coefficient of heat transfer and negligible losses to the environment are possible.
The solar hot water enameled boiler WPS/E is used for the preparation of hot sanitary water in households, catering facilities and other facilities, where we want to always have a larger amount of hot sanitary water available. The advantage of the WPS/E boiler is in the use of different energy sources (solar energy, heat pumps, electricity, gas, biomass), a larger area of the exchanger for heating at lower temperatures using a heat pump, the possibility of preparing a larger amount of hot water, rational consumption of energy sources (heat pumps, gas, biomass, electrical energy), excellent insulation and a modern, optimal construction basis, all of which is reflected in a significantly lower cost of energy invested per unit of prepared hot water.
Based on the quality and thickness of the materials used, APAMET buffer and DHW tanks are dedicated to long-term use.
The internal surface of the APAMET buffer and DHW tanks are protected with an internal enamel layer of 250 μ – 450 μ thickness, which design clearly reduces the possibility of damage and increases its service life.